Daikin REYQ-T VRV IV Heat Recovery Condenser 22.4kW – 151.2kW

Key Features

  • COPs of up to 8 !
  • Covers all thermal needs of a building via a single point of contact
  • “Free” heating and hot water production
  • Simultaneous cooling and heating
  • Incorporates VRV IV standards & technologies
  • Weather dependant Variable Refrigerant Temperature function
  • Automatic charging & testing
  • Automated refrigerant containment check
  • Up to 1,000m total piping length
  • Keep your system in top condition via our i-Net service

 

Download Leaflet

 

SKU: REYQ-T Categories: , Tags: , , , ,

 

Product Features

  • Fully integrated solution with heat recovery for maximum efficiency with COPs of up to 8 !
  • Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains
  • "Free" heating and hot water production provided by transferring heat from areas requiring cooling to areas requiring heating or hot water
  • The perfect personal comfort for guests/tenants via simultaneous cooling and heating
  • Incorporates VRV IV standards & technologies: Variable Refrigerant Temperature, continuous heating, VRV configurator, 7 segment display and full inverter compressors, 4-side heat exchanger, refrigerant cooled PCB, new DC fan motor
  • Customize your VRV for best seasonal efficiency & comfort with the weather dependant Variable Refrigerant Temperature function. Increased seasonal efficiency with up to 28%. No more cold draft by supply of high outblow temperatures
  • Continuous comfort: Unique continuous heating technology makes VRV IV the best alternative to traditional heating systems
  • VRV configurator software for the fastest and most accurate commissioning, configuration and customisation
  • Outdoor unit display for quick on-site settings and easy read out of errors together with the indication of service parameters for checking basic functions.
  • Free combination of outdoor units to meet installation space or efficiency requirements
  • Fits any building as also indoor installation is possible as a result of high external static pressure of up to 78.4 Pa. Indoor installation leads to less piping length, lower installation costs, increased efficiency and better visual aesthetics
  • Simplified installation & guaranteed optimal efficiency with automatic charging & testing
  • Easy compliance with F-gas regulation thanks to automated refrigerant containment check
  • Wide piping flexibility: 30m indoor height difference, maximum piping length: 190m, total piping length: 1,000m
  • Possibility to extend the operation range in cooling down to -20°C for technical cooling operation such as server rooms
  • The ability to control each conditioned zone individually keeps VRV system running costs to an absolute minimum
  • Spread your installation cost by phased installation
  • Keep your system in top condition via our i-Net service: 24/7 monitoring for maximum efficiency, extended lifetime, immediate service support thanks to failure prediction and a clear understanding of operability and usage