Fujitsu Airstage Standard Range KM Series Large Room / Special Cooling Wall Mounted - R32
Discover the exceptional comfort of the Fujitsu KM Series for large-room or server room applications (KMTB models). Engineered with high-density heat-exchanger technology and R32-refrigerant, this high-efficiency system delivers powerful cooling and heating while retaining a sleek wall-mounted profile. Ideal for open-plan living spaces or commercial environments, the range pairs whisper-quiet operation with smart-device control compatibility and professional installation features to ensure year-round comfort, energy savings and flexible performance.
|
Model Reference |
Cool Capacity (kW) |
Heat Capacity (kW) |
Max Pipe (m) |
EuP Lot 10 Energy Rating |
Suggested MCB (A) |
Pipe Size Gas (inch) |
Pipe Size Liquid (inch) |
Electrical Supply |
Wi-Fi Control |
||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Indoor Unit | Outdoor Unit | SCOP | SEER | ||||||||
| ASEH30KMTB | AOEH30KMTB | 8.0 | 8.8 | 50 | 4.50 | 6.68 | 25 | 5/8 | 3/8 | Single | Optional |
| ASEH36KMTB | AOEH36KMTB | 9.4 | 10.1 | 50 | 4.50 | 6.10 | 25 | 5/8 | 3/8 | Single | Optional |
| For more information, see Technical Specifications. |
|||||||||||
Key features
Elegant Design for Modern Spaces
Elegant, smart square design with refined ridge-line detailing that complements modern interiors, paired with a high-performance, enlarged heat exchanger that delivers superior energy savings and powerful operation in a compact unit.
Convenient Smart Device Control Anywhere
With the optional WLAN adapter (UTY-TFSXH3), the air conditioner can be controlled remotely from any location using your smartphone or tablet. By installing the AIRSTAGE Mobile app, users gain full access to operating modes, temperature settings, and scheduling features, enabling effortless and flexible climate management whether at home or away.
Stable Cooling Performance for High-Heat Load Environments
The Special Cooling function enables consistent cooling performance even when outdoor temperatures are low, making it suitable for rooms with high internal heat loads. When used with the wired remote controller (UTY-RNRYZ5), the system maintains reliable operation in low-humidity environments, providing controlled cooling where constant temperature management is essential.
* Terms and conditions apply. See Fujitsu Airstage Catalogue for more details.
Energy-Saving Operation with Occupancy Sensor
The integrated occupancy sensor detects room activity and automatically reduces the air conditioner’s capacity when the space is unoccupied, helping to save energy. When movement is detected again, the system seamlessly returns to the previous operating mode for consistent comfort.
Elegant Design for Modern Spaces
Elegant, smart square design with refined ridge-line detailing that complements modern interiors, paired with a high-performance, enlarged heat exchanger that delivers superior energy savings and powerful operation in a compact unit.
Convenient Smart Device Control Anywhere
With the optional WLAN adapter (UTY-TFSXH3), the air conditioner can be controlled remotely from any location using your smartphone or tablet. By installing the AIRSTAGE Mobile app, users gain full access to operating modes, temperature settings, and scheduling features, enabling effortless and flexible climate management whether at home or away.
Stable Cooling Performance for High-Heat Load Environments
The Special Cooling function enables consistent cooling performance even when outdoor temperatures are low, making it suitable for rooms with high internal heat loads. When used with the wired remote controller (UTY-RNRYZ5), the system maintains reliable operation in low-humidity environments, providing controlled cooling where constant temperature management is essential.
* Terms and conditions apply. See Fujitsu Airstage Catalogue for more details.
Energy-Saving Operation with Occupancy Sensor
The integrated occupancy sensor detects room activity and automatically reduces the air conditioner’s capacity when the space is unoccupied, helping to save energy. When movement is detected again, the system seamlessly returns to the previous operating mode for consistent comfort.
Fujitsu Airstage Standard Range KM Series Large Room / Special Cooling Specification Table
| Technical Data | Model Number (Indoor Unit + Outdoor Unit) | |
|---|---|---|
| ASEH30KMTB | ASEH36KMTB | AOEH30KMTB | AOEH36KMTB |
| Power Source | Single phase, ~230 V, 50 Hz | Single phase, ~230 V, 50 Hz |
| Cooling Capacity (kW) /td> | 8.0 | 9.4 |
| Heating Capacity (kW) - Nominal | 8.8 | 10.1 |
| UK Total Cooling / UK Sensible Cooling | 5.82 / 6.70 | 7.55 / 8.87 |
| Input Power Cooling/Heating (kW) | 2.33 / 2.20 | 3.16 / 2.73 |
| EER (W/W) | 3.43 | 2.97 |
| COP (W/W) | 4.00 | 3.70 |
| Pdesign Cooling/Heating (-10°C) kW | 5.2 / 4.88.0 / 6.5 | 9.4 / 7.1 |
| SEER (W/W) | 6.68 | 6.10 |
| SCOP (W/W) | 4.50 | 4.50 |
| Energy Efficiency Class - Cooling | A++ | A++ |
| Energy Efficiency Class - Heating | A+ | A+ |
| Annual Energy Consumption Cooling / Heating (kWh/a) | 419 / 1,994 | 534 / 2,189 |
| Moisture Removal Volume (L/h) | 2.6 | 3.8 |
| Sound Pressure Level Indoor Cooling - H/M/L/Q (dBA) | 50 / 44 / 40 / 33 | 50 / 44 / 40 / 33 |
| Sound Pressure Level Indoor Heating - H/M/L/Q (dBA) | 49 / 44 / 39 / 33 | 49 / 44 / 39 / 33 |
| Sound Pressure Level Outdoor Cooling / Heating - High (dBA) | 53 / 55 | 55 / 55 |
| Airflow Rate Indoor/Outdoor (Cooling) High (m3/h) | 1,330 / 3,750 | 1,330 / 3,750 | <
| Airflow Rate Indoor/Outdoor (Heating) High (m3/h) | 1,330 / 3,750 | 1,330 / 3,750 |
| Net Dimensions H x W x D Weight - Indoor (mm / kg) | 340 × 1,150 × 280 / 18.5 | 340 × 1,150 × 280/ 18.5 |
| Net Dimensions H x W x D Weight - Outdoor (mm / kg) | 788 × 940 × 320 / 52.0 | 788 × 940 × 320 / 52.0 | <
| Remote Controller Type (Supplied With Unit | Wireless | Wireless |
| Interconnecting Cable (Suggested cable size 1.5mm) | 3 Core + Earth | 3 Core + Earth |
| Suggested MCB Size (A) | 25 | 25 |
| Max. Operating Current - Cooling / Heating (A) | 21.0 / 21.0 | 21.5 / 21.5 |
| Connection Pipe Diameter - Liquid/Gas (Inch) | 3/8 & 5/8 | 3/8 & 5/8 |
| Max. Pipe Length (m) | 50 | 50 |
| Pre-Charge Pipe Length (m) | 30 | 30 |
| Max. Height Difference (m) | 30 | 30 |
| Refrigerant Type / Global Warming Potential | R32 / 675 | R32 / 675 |
| Refrigerant Charge / CO2eq-T (g) | 1900 / 1.283 | 1900 / 1.283 |
| Refrigerant Additional Charge (g/m) | 40 | 40 | <
| Operating Range - Cooling (°CDB) | -15 to 46 | -15 to 46 |
| Operating Range - Heating (°CDB) | -15 to 24 | -15 to 24 |